5.14.8. Removal and installation of a fuel stageFuel stage remove for replacement at damage (breakage of unions), for replacement of atomizers or for access reception to other knots.
It be required to you: keys on 10, on 12.
THE NOTE
Necessity of a detachment of a hose from the fuel filter, instead of from a stage is caused by that for its detachment from a stage the special adaptation (the good advice see more low) is required, to use which expediently only at hose or stage replacement.
|
GOOD ADVICE
The tip of a hose of giving of fuel in a stage is fixed on the stage union цанговым by a clip. For easing of this clip it is necessary to get the special adaptation or to make it by own strength as it is described more low.
|
Wrap up the union of a stage a tin strip, having made similarity of the plug …
… move the plug into a hose tip so that it was possible to unclench pads цангового a clip …
… also disconnect a tip of a hose from the stage union.
|
|
3. Remove from the union of a regulator of pressure of fuel a vacuum hose.
|
4. Disconnect from a regulator of pressure a hose fuel plum, having compressed its clamps.
|
|
|
5. Move upwards a clamp колодки a plait of wires of an atomizer …
|
6. … also disconnect pad. Similarly disconnect колодки a plait of wires from other atomizers and take a plait of atomizers aside.
|
|
|
7. Turn out two bolts of fastening of an arm of a cable of a drive throttle заслонки to an inlet pipe …
|
8. … also take a cable aside together with an arm.
|
|
|
9. Turn out two bolts of fastening of a fuel stage to an inlet pipe …
|
10. … also remove a stage, taking out atomizers from apertures of an inlet pipe.
|
THE PREVENTION
If at stage removal any of atomizers remains in an inlet pipe, necessarily replace a clamp of this atomizer.
|
THE NOTE
Sealing rings of atomizers replace new at each removal or dismantling of a fuel stage.
|
12. Establish a fuel stage in sequence, to return dismantling and removal, having greased sealing rings of atomizers with engine oil.
13. Having connected pipelines to a stage, start up the engine and check up tightness of connections of pipelines and consolidations of atomizers.
|